MIL-DTL-85052/1C FUEL AND PETROLEUM BASED HYDRAULIC FLUID RESISTANT CLAMPS

Nitrile

TestTest MethodRequired Original PropertiesFuel Immersion MIL-DTL-5624, JP-4, 163 hrs at +100 oF 1/Hydraulic Fluid Immersion MIL-PRF-5606 70 hrs at +156 oF 1/Heat Aging 70 hrs at +275 oF
Hardness durometer “A”ASTM-D224065-75- 20 Max-15 Max+10 Max
Tensile strength (PSI) ASTM-D4122000 Min-30 % Max-10 % Max-40 % Max
Elongation (%) ASTM-D412500 Min- 10 % Max- 10 % Max-75 % Max
Tear strength (PPI)ASTM-D624 DIE “B”300 Min- 35 % Max-10 %Max-40 % Max
Volume change (%) 1.After conditioning 2. After 24 hrs air dryASTM-D471+15% Max +10% Max+10% Max +10% Max-10 % Max
Specific gravity-As Measured--+/- 2 %
Compression SetMil-DTL-85052
Ozone ResistanceMil-DTL-85052
FlammabilityMil-DTL-85052